We ran a gas pipeline report against DNV-RP-F104
The gas pipeline report we checked for hydrogen, now against DNV-RP-F104 for CO₂: 12 findings, led by running-fracture arrest.
By Leo Ruspini — Nuclear engineer, PhD · Co-founder & CEO, normify.ai
Last month we checked a gas pipeline report against DNV-RP-F123, DNV's practice for hydrogen pipelines. Hydrogen added 26 findings to what the gas standard had already raised.
Hydrogen isn't the only new fluid looking for an old pipeline. Carbon capture projects need CO₂ pipelines, and a gas line at the end of its field life, already running to an offshore reservoir, is an obvious candidate. DNV covers that case in DNV-RP-F104, Design and operation of carbon dioxide pipelines, with a full section on re-qualifying existing pipelines for CO₂.
So we ran the same report again.
The test
Cormorán is the fictional 18-inch subsea gas export pipeline from the hydrogen test: X65 seam-welded pipe, walls of 14.3 and 15.9 mm, 32 km from the platform to a terminal on Tierra del Fuego, in service since 2013. Its design report was written to DNV-ST-F101.
We changed one thing: the planned new service. Instead of hydrogen, the report now says the line will carry captured CO₂ in dense phase, in the reverse direction, from the onshore terminal to the platform for injection into the depleted Cormorán reservoir. Every number, check and inspection record is the same as in the hydrogen test.
Keeping it fair
As before, a 10-page summary report doesn't carry every piece of evidence a standard asks for, and the DNV-ST-F101 check had already found 46 things to complete for natural gas.
F104 doesn't replace F101. It sits on top of it. So of the 20 findings in the F104 check, we removed the 8 that the F101 check had already raised: pressure testing, overpressure protection, flaw acceptance, seals, emergency response, inspection status and document control. What's left is what CO₂ adds.
What CO₂ adds
12 findings, 10 of them critical. All 12 are undocumented. None is a conflict.
That's the first difference from hydrogen. Under F123 the gas-era report contradicted the new practice in five places: the safety class, every safety factor, the fatigue method, the gas detectors and the requalification itself. Under F104 it contradicts nothing.
The rulebook explains why. F104 classes CO₂ as a category E fluid, the same category hydrogen falls into, but its hoop-stress design factors match what DNV-ST-F101 already gives for the safety classes the report uses (§3.3.2, §5.5.2). Fatigue is no bigger concern than for a hydrocarbon line as long as no free water forms (§5.7.1). The steel rules mostly hold.
What changes is everything about the fluid itself: what's in it, how it behaves in the pipe, and what happens when it gets out.
The main finding: stopping a running crack
If a CO₂ pipeline ruptures, a crack can run along the pipe, far beyond the point of failure. In a gas line the pressure at the crack tip drops fast and the steel stops it. Dense-phase CO₂ decompresses slowly, so it keeps pushing on the crack tip at a pressure that would have let a gas-line crack stop.
The report proves arrest with the Battelle method for its export gas, and for gas the numbers pass easily. F104 changes the picture in three ways (§5.6):
- The usual Battelle correction factors, the kind the report uses, are shown to be non-conservative for CO₂.
- The simplified arrest check F104 offers for dense phase is only valid for pipe with a toughness of 250 J or more. Cormorán's delivered heats go down to 198 J.
- Outside that range, arrest has to be shown another way: full-scale testing or a method validated for the case.
The steel is the same steel that passed for gas. The proof that it stops a running crack doesn't carry over.
What it depends on: the stream
Composition, water and corrosion (§4.3.2, §4.2.7, §5.2.2). The report has no CO₂ composition specification: no impurity limits, no water limit, no upset cases. Captured CO₂ carries water, oxygen, H₂S, SOx and NOx in amounts that depend on the capture plant. Impurities change how the stream decompresses, so even the fracture check above can't be closed without them. The report's corrosion and sour-service conclusions rest on dry natural gas with under 2 ppmv H₂S. F104 wants the water content controlled so that no free water forms anywhere, in any operating or upset case, with a margin of at least two on the water limit.
What else the report doesn't document
How the line will run (§4.2, §4.3.3). The hydraulics in the report are for gas flowing to shore. CO₂ will flow the other way, around six times denser than the gas the report uses (145 kg/m³), with different pressure profiles, static head and seasonal effects. There's no capacity case, no reduced-rate case and no operating envelope for CO₂.
Letting it out (§4.4.4, §6.2.3). CO₂ cools hard when it expands, and below 5.2 bar it can turn to dry ice. F104 asks for a permanent vent station that can depressurise the whole line, a controlled blowdown, and a first-fill procedure that avoids solids. The line was also dried to a dew point of −20 °C before it first carried gas in 2013. F104 recommends −40 to −45 °C before filling with CO₂.
When it gets out by accident (§8.3.5, §3.4). The QRA models a methane release. CO₂ is heavier than air, toxic at high concentrations, and spreads along the ground and collects in low points, which matters at a landfall. The QRA has no CO₂ dispersion, no toxic exposure model and no subsea CO₂ release case.
Watching for it (§4.4.3, §7.5.2). The gas detectors at the landfall are calibrated for methane, and nothing monitors water at the new inlet.
The conversion itself (§8.1.2, §7.3.1). The report presents itself as the basis for re-qualification, but the steps F104 lays out aren't done, and the inspection strategy has no CO₂ threat screening or procedure for running inspection tools in a CO₂ line.
Two fluids, one pipeline
- Hydrogen (DNV-RP-F123): 26 findings added, 18 critical, 5 conflicts with the gas-era report. The question is whether the steel still holds.
- CO₂ (DNV-RP-F104): 12 findings added, 10 critical, no conflicts. The question is whether the fluid is under control.
Hydrogen changes the rules for the steel: new safety classes, new fatigue methods, material tests in hydrogen. CO₂ mostly leaves those rules alone and moves the risk to the fluid: what's in it, what it does to the steel when it's wet, how a crack runs through it, and what happens to people nearby when it leaks.
Same pipeline, same report, two different work lists. That's why we check a document against the norm it now has to meet, not the one it was written for. Each finding comes with the clause, the passage in the document and a recommendation.
One run per norm, on a fictional document we wrote. Counts vary between runs; the findings above are from the reports of 12 November 2026 (DNV-RP-F104) and 19 October 2026 (DNV-ST-F101). The hydrogen numbers are from our earlier post.
Sources
- DNV-RP-F104 Design and operation of carbon dioxide pipelines (February 2021, amended September 2021) and DNV-ST-F101 Submarine pipeline systems. Both are licensed DNV documents; this article refers to clause numbers only.
- Our hydrogen test: We ran a gas pipeline report against DNV-RP-F123